Datenhighway
EICHLER – Repair and Sale

Frequency Converter – Driving Automation

Intelligent Search for Components

Search according to your product code, category of product or manufacturer and you will find your requested component fast and easy. Should you nevertheless not be able to trace the part you are looking for – our experts will gladly help you Tel: +49 8196 9000-110.

Converters – Frequency Converters for power supply and control of electrical machinery and motors

Converters and frequency converters belong to the family of power modules in order to enable the direct supply of electrical engines and machinery with the necessary AC current. Some frequency converters, apart from being able to control and convert frequency and amplitude, also have sensoric input to control and evaluate additional parameters such as the current potition of the rotor and the number of revs running. Depending on the make of machinery some frequency converters are fitted with either single or 3-phase AC power supply. Some models are even able to convert a single phase power supply into 3-phase supplies in order to service rotary current electrical engines.

Repair

EICHLER is specialized in servicing frequency converters of numerous manufacturers. All modules are specifically repaired down to the individual component according to the actual damage recorded.

Sale

EICHLER offers a large variety of current and discontinued types of converters and frequency converters. Every module is fully tested and fitted with a 24 months warranty.

Product Overview

Should you not have the specific item number at hand kindly refer to the product overview. Here you will find all combined modules available online.

Product Overview – Converters – Frequency Converters

Following you fill see an overview of all converters available online. For further details referring to the individual item please klick on the article code accordingly. Should you nevertheless not be able to trace the item requested kindly use the intelligent search for components or simply give us a call:  +49 8196 9000-110

Article Name Article Description Scope Article Group Name Manufacturer
MC3011-403-4-00 SEW MOVITRAC Frequenzumrichter MC3000 11,0 KW; 4Q; 3x 400V; 8256535 Drive Technology Frequency Converter SEW
MC31B075-503-4-00 SEW MOVITRAC Umrichter MC31B 7,5 kW Drive Technology Frequency Converter SEW
6SE6090-0AF00 SIMOVERT PX TRANSISTORPULSUMRICHTER 9A/ 230V Drive Technology Frequency Converter SIEMENS
6SE7016-1EA61-Z SIMOVERT MASTERDRIVES VC KOMPAKT, UMRICHTER, IP20 3AC 380-480V, 50/60HZ, 6,1 A TYPENLEISTUNG: 2,2KW DOKUMENTATION AUF CD Drive Technology Frequency Converter SIEMENS
MDV60A0075-5A3-4-0T SEW MOVIDRIVE Umrichter MDV60A 7,5 KW; Technologieausführung; Drive Technology Frequency Converter SEW
MDX61B0150-503-4-00 SEW MOVIDRIVE Frequenzumrichter 15kW; 3x380..500V; 50/60Hz; 08279640 Drive Technology Frequency Converter SEW
6SE0102-1AC21-0AA5 DYNAVERT T 2T2A-05690-007 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 7,5KW (690V) 610*225*320MM IP20, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0102-1AC21-3AA5 DYNAVERT T 2T2A-05690-011 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 11KW (690V) 610*225*320MM IP20, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0102-1AC21-8AA5 DYNAVERT T 2T2A-05690-015 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 15KW (690V) 610*225*320MM IP20, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0102-1AC22-5AA5 DYNAVERT T 2T2A-05690-022 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 22KW (690V) 610*225*320MM IP20, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA15-5AA5 DYNAVERT T 2X3A-85400-002 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 2,2KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA17-0AA5 DYNAVERT T 2X3A-85400-003 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 3KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA21-0AA5 DYNAVERT T 2X3A-85400-004 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 4KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA21-3AA5 DYNAVERT T 2X3A-85400-005 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 5,5KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA21-8AA5 DYNAVERT T 2X3A-85400-007 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 7,5KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA22-5AA5 DYNAVERT T 2X3A-85400-011 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 11KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA23-7AA5 DYNAVERT T 2X3A-85400-015 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 15KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA24-8AA5 DYNAVERT T 2X3A-85400-022 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 22KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA25-8AA5 DYNAVERT T 2X3A-85400-030 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 30KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA27-8AA5 DYNAVERT T 2X3A-85400-037 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 37KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA28-8AA5 DYNAVERT T 2X3A-85400-045 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 45KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA31-1AA5 DYNAVERT T 2X3A-85400-055 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 55KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA31-5AA5 DYNAVERT T 2X3A-85400-075 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 75KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA31-8AA5 DYNAVERT T 2X3A-85400-090 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 90KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA32-1AA5 DYNAVERT T 2X3A-85400-110 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 110KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA32-5AA5 DYNAVERT T 2X3A-85400-132 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 132KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KA33-0AA5 DYNAVERT T 2X3A-85400-160 3AC 230-500V, TN/TT 50/60 HZ TYP.MOTOR POWER 160KW (400V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 MAINS FILTER CL.A ACC.TOEN55011 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB14-5AA5 DYNAVERT T 2X3A-85500-002 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 2,2KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB15-5AA5 DYNAVERT T 2X3A-85500-003 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 3KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB17-0AA5 DYNAVERT T 2X3A-85500-004 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 4KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB21-0AA5 DYNAVERT T 2X3A-85500-005 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 5,5KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB21-3AA5 DYNAVERT T 2X3A-85500-007 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 7,5KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB21-8AA5 DYNAVERT T 2X3A-85500-011 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 11KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB22-5AA5 DYNAVERT T 2X3A-85500-015 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 15KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB23-7AA5 DYNAVERT T 2X3A-85500-022 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 22KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB24-8AA5 DYNAVERT T 2X3A-85500-030 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 30KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB25-8AA5 DYNAVERT T 2X3A-85500-037 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 37KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB27-8AA5 DYNAVERT T 2X3A-85500-045 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 45KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB28-8AA5 DYNAVERT T 2X3A-85500-055 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 55KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB31-1AA5 DYNAVERT T 2X3A-85500-075 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 75KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB31-5AA5 DYNAVERT T 2X3A-85500-090 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 90KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB31-8AA5 DYNAVERT T 2X3A-85500-110 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 110KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB32-1AA5 DYNAVERT T 2X3A-85500-132 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 132KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB32-5AA5 DYNAVERT T 2X3A-85500-160 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 160KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KB33-0AA5 DYNAVERT T 2X3A-85500-200 3AC 230-500V, IT 50/60 HZ TYP.MOTOR POWER 200KW (500V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KC21-0AA5 DYNAVERT T 2X3A-85690-007 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 7,5KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KC21-3AA5 DYNAVERT T 2X3A-85690-011 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 11KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KC21-8AA5 DYNAVERT T 2X3A-85690-015 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 15KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KC22-5AA5 DYNAVERT T 2X3A-85690-022 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 22KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
6SE0143-1KC23-4AA5 DYNAVERT T 2X3A-85690-030 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 30KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER Drive Technology Frequency Converter SIEMENS
Showing 2501 - 2550 of 7.869 results.

Repairs Converters – Frequency Converters

In the field of driving automation EICHLER offers a large variety of repair and maintenance for converters and frequency converters. Numerous kinds of make such as Siemens, SEW, Lenze, Danfoss, Bosch, ABB - amongst many others - can be serviced at our works. Especially discontinued types of frequency converters cause a much larger investion in costs towards having to migrate this system compared to an expert repair.

Possible Repairs – Converters – Frequency Converters

  • Removal of possible faults within the CU
  • Repairs on the Internal Power Supply
  • Repairs of faults within the intermediate circuit
  • Maintaining the drive-level of amplifiers
  • Trouble Shooting on electric recovery systems
  • Problems with the interface
  • Clearing possible faults within the internal safety controls
  • Strategic preventative maintenance

Quality management according to ISO 9001:2015

Certified workflow guarantees a consistently high quality of service when testing and repairing your component.

Nuclear Safety Committee 1401

As one of the first service providers, EICHLER is authorised to repair and sell automation and control technology in the nuclear sector.

Environmental management according to ISO 14001:2015

Standardized procedures for cleaning, repair and, if necessary, the disposal of components ensure a sustainable, environmentally sound use of resources.

Sale on a large variety of new and refurbished frequency converters

EICHLER offers a large variety of current and discontinued types of converters. Every module is fully tested and fitted with a 24 months warranty and enables you to build up or restock your spareparts deposit.

We stock more than 30.000 components

To be able to offer you a large variety of current and discontinued devices EICHLER manages an own stock level of over 30.000 components. This enables us to service you with the necessary module as very short notice – even in case of a breakdown in your system.

Function is fully tested

Every module you purchase at EICHLER is fully tested on all relevant functions before it leaves our works. The combination of highly experienced staff together with our specific Trial- and Testracks give you the necessary safety on the purchase of refurbished automation equipment.

Warranty included

Full trial runs give you the guarantee of the highest possible level on repair service and function of the part sent to us. The item returned to is fitted with a 24 months warranty. If you wish to have an optional test of all parameters we are able to extend this warranty up to 30 months.

Your Direct Line to EICHLER GmbH

Emergency-Hotline - Machine Breakdown

24/7 Spare Parts Service

Service-Hotline - Sales, Maintenance Contracts and Repairs

Technical Trainings - Information & Booking

Life Cycle Management - Information & Appointments

Purchase of Overstockings

Help from Experts:
+49 8196 9000-110

Our Business Hours:

Mo – Thu
7-30 am to 5 pm
Fri
7-30 am to 2-30 pm

SIEMENS SIMATIC®, SIMODRIVE®, SIMOREG®, SIMOVERT®, SINAMICS®, SINAUT®, SINUMERIK®, SIPART®, SITOP®, SIWAREX®, MASTERDRIVES® TELEPERM® are registred trademarks of Siemens AG.